Stack support DN 75mm - SMU S
Code article : 156512
Description
The stack support of the SMU S range take up the forces generated by the weight of the water column and/or the accidental internal pressure (loading of the network). They are similar to a mono-directional stop, the axial force to be taken up being directed in the direction of water flow, i.e. upstream/downstream. The stack support can take up the forces of up to 15 meters of water column. It consists of a cast iron flanged pipe, an EPDM insulating gasket and a cast iron lug ring.
Product variants
Article | DN | dn | Angle | Length | Height | Width | Weight |
---|---|---|---|---|---|---|---|
156413 | 50 | - | - | 195 | 17 | 108 | 1 |
156512 | 75 | - | - | 218 | 220 | 133 | 3.1 |
156657 | 100 | - | - | 259 | 220 | 162 | 4.3 |
156793 | 125 | - | - | 275 | 220 | 187 | 5.4 |
156904 | 150 | - | - | 300 | 220 | 222 | 7.2 |
157014 | 200 | - | - | 362 | 220 | 278 | 10.5 |
157097 | 250 | - | - | 444 | 300 | 354 | 19.1 |
157160 | 300 | - | - | 498 | 300 | 406 | 26.5 |
All dimensions are in mm and nominal weights are in kg
Technical infos & product description
Product description
The stack support of the SMU S range take up the forces generated by the weight of the water column and/or the accidental internal pressure (loading of the network). They are similar to a mono-directional stop, the axial force to be taken up being directed in the direction of water flow, i.e. upstream/downstream. The stack support can take up the forces of up to 15 meters of water column. It consists of a cast iron flanged pipe, an EPDM insulating gasket and a cast iron lug ring.
Recommended use :
- Soil and drain
- Standard Use
- Domestic use
- Intensive Use
- Fat Wastewater
- Rainwater
Major benefits :
- Performances guaranteed with marks delivered by third party.
- High level of fire safety with the excellent fire resistance up to 240 minutes according to configuration (mostly requires no special fire protection saving time and cost).
- Best acoustic comfort.
- Easiness of installation due to mechanical couplings assembled with simple tools.
- Adaptable to all configurations with available accessories connecting cast iron with other materials.
- Limited maintenance operation thanks to technical and mechanical properties of cast iron.
Technical infos
- Hot water resistance: 24h at 95°C.
- Thermal cycle resistance: 1500 cycles between 15°C and 93°C.
- Chemical resistance for 2 ≤ pH ≤ 12.
- Salt spray resistance: more than 350h.
Coating description :
External coating : Red-brown, anti-corrosive acrylic primer paint, average dry film thickness 40 μm.
Internal coating : Two-component ochre colored epoxy coating, average dry film thickness of 130 μm.
- Material :
- Industry product standards :
- Range Fire Classification : A1
- Acoustic Performance : Lsc ≤ 5dB(A) according to EN 14366
- Percentage of Recycled Content : 97%
- Recycling Information : 97%
Tutoriels & videos